Motor Replacement
Relieve pressure; page 3.
NOTE: See Fig. 12 except where noted.
1. Relieve pressure.
2. Try to stop the pump with the piston rod (107) in its
lowest position. To lower the piston rod manually,
rotate the motor fan blades. Use a screwdriver to
push the retaining spring (18) up and push out the
pin (17). See Fig. 10.
3. Remove the screws (56) and lower the junction
box (59). Disconnect the motor wires and the
pressure control wire (A) from the motor start
board. Refer to Fig. 13 on page 14.
4. Remove the front cover (13).
5. Turn the displacement pump rod (107) so the pin
hole aligns with the bottom drive housing screw
(19). See Fig. 11. Remove the three drive housing
screws and lockwashers (19,6). Also see Fig. 12.
6. Remove the two motor screws (5) and the lock
washers (6).
7. Tap the lower rear of the drive housing (11) with a
plastic mallet to loosen the motor. Pull the drive
housing straight off the motor while guiding the
harness (A) from the motor. Do not allow the gear
(16) to fall. Read the CAUTION on page 15.
8. Remove the two screws (46) and lift the motor off
the base (66).
9. Align the new motor with the base and reinstall the
screws (46).
10. Assemble the drive housing to the motor. Follow
steps 8 to 10 on page 15.
11. Connect the wires in the junction box. Refer to Fig.
13 on page 14. Install the junction box.
12. Connect the piston rod (107) to the drive housing;
see page 12, Installing the Pump , Step 2 and the
WARNING following it.
17
18
15
Fig. 10
01068
107
19,6
Fig. 11
01074
Torque to 2.4 N.m (21 in–lb)
05119
Fig. 12
Quantity of three
Quantity of one
19
6
13
34
31
59
56
12
16
11
4
5
6
46
B
C
A
Vue de la page 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 23 24

Commentaires sur ces manuels

Pas de commentaire